Skip to main content

Overview

General comment

Production covered

Chip-on-wafer-on-substrate assembly: compute and memory dies are mounted on a silicon interposer carrying through-silicon vias, and that interposer is then attached to an organic substrate. Functional unit is one package STARTED: the reference flow is a single package entering assembly, and the activities listed run through completed assembly and final test of that package.

Modelling choices

By the count-once yield-ownership convention, the gross-up from packages started to good packages is carried by the consuming IC or component dataset, not here.

Technology
CoWoS-S
Geography
Global average data from equipment vendor specifications and industry literature

System boundary

System boundary - Chip-on-Wafer-on-Substrate (Silicon) packageSystem boundary figure: identity, gate in, entering flows, the dashed system boundary and the unit processes inside it, the reference product, emissions and waste, and below it the flows that are recorded but not quantified. No inventory quantities.Chip-on-Wafer-on-Substrate (Silicon) packageGATE INRaw materials and sub-componentsENTERING FLOWSElectricityWaterProcess gasesProcess chemicalsMaterialsSYSTEM BOUNDARYMODELLED UNIT PROCESSES, BY CLASSAssemblyFlipchip bumpingWafer backgrindingWafer backgrindTCB bondingBall attach reflowUnderfill dispensePackage singulationFlux applicationSolder reflowUnderfill moldingLid attachLithographyLitho dry 248PlanarisationCMP metal copperTestPackage final test logic SoCBurn in testInterconnectCoWoS TSV DRIECoWoS TSV Cu fillWLCSP RDL per layerThermalUnderfill cureLid attach cureDepositionThermal oxidationPVD barrierOtherBGA substrateHBM stack placementDie placementREFERENCE PRODUCTChip-on-Wafer-on-Substrate(Silicon) packageAssembled and tested productEMISSIONS AND WASTEEmissions to airEmissions to waterWaste routesRECORDED BUT NOT QUANTIFIEDIn scope, left out of the quantified inventoryCut off below the significance threshold, or with no background dataset available - each is listed with its reason3FLOWSsystem boundaryreference flowentering flowemission / waste

The figure groups this dataset's unit processes by class. It is not a count of manufacturing steps — each process runs over as many passes as the flow requires, and those pass counts ship with the dataset.

Download this figure (SVG)

Data quality and references

Composite DQI 1.8 Very good
Reliability
2.7
Completeness
2.1
Temporal
1.5
Geographic
2.0
Technological
1.3

Pedigree scores follow the ecoinvent data-quality matrix: 1 is the best attainable, 5 the weakest. The composite is their aggregate.

Sampling procedure
Equipment vendor specifications, academic papers, industry literature
Coverage status
Partial
Pedigree-scored source files
24 — the source records behind this dataset's manufacturing operations. Each carries the five pedigree axes above; the composite DQI aggregates them.

Technosphere inputs

44 flows. Quantities are not published; they ship with the dataset on Circa.

Elemental fluorine (F2) Process gasg · -70% / +400.1%
Source citations
Upstream REEL dataset
Fluorine (F2)
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
-70% / +400.1% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
SF6 production Process gasg · -4.3% / +7.1%
Source citations
Upstream REEL dataset
Sulfur hexafluoride (SF6)
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
-4.3% / +7.1% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
C4F8 production Process gasg · -12.5% / +4.2%
Source citations
Upstream REEL dataset
Octafluorocyclobutane (c-C4F8)
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
-12.5% / +4.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
KrF/DUV Photoresist Process chemicalg · -16.7% / +25.1%
Derivation basis
  • Calculated by the manufacturing model. The linked REEL dataset carries the upstream life cycle sources.

No source is attached to this row.

Source citations
Not stated
Upstream REEL dataset
ArF Photoresist (193nm)
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
-16.7% / +25.1% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
TMAH Developer (2.38% solution) Process chemicalg · ±22.6%
Derivation basis
  • Developer usage

The sources for this row are listed below.

Source citations
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
±22.6% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
CMP Slurry (Copper) Process chemicalg · -27.8% / +33.2%
Derivation basis
  • Calculated from barrier removal rate

The sources below come from the manufacturing operations behind this row.

Source citations (specific to this process)
Inherited, rolled up from the contributing process steps:
Upstream REEL dataset
Copper CMP Slurry
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
-27.8% / +33.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
ArF Photoresist Process chemicalg · -33.3% / +66.7%
Upstream REEL dataset
ArF Photoresist (193nm)
Background dataset
Modelled by REEL; see the upstream dataset above.
Uncertainty
-33.3% / +66.7% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Water supply (municipal) Waterm3 · -35.3% / +43.2%
Derivation basis
  • Calculated from process-water and ultrapure-water demand across all manufacturing operations, plus facility water allocated to each finished unit. The fresh intake shown is that demand less the share reused under the water-recycling scenario this dataset assumes, and wastewater follows the same balance.

No source is attached to this row.

Source citations
Not stated
Upstream REEL dataset
Water Supply (Municipal)
Background dataset
Modelled by REEL; see the upstream dataset above.
Notes
Net fresh-water intake, supplied as municipal water
Uncertainty
-35.3% / +43.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
m3
Electricity, Taiwan (TW) ElectricitykWh · -52.7% / +76.7%
Derivation basis
  • Calculated from equipment energy across all manufacturing operations. It also includes the assembly site's facility overhead: air handling and cleanroom conditioning, chilled water, compressed dry air, exhaust and dust collection, wastewater treatment and uninterruptible power.

The sources below come from the manufacturing operations behind this row.

Sources (inherited)
Inherited, rolled up from the contributing process steps:
Background data
ecoinvent 3.12
Background dataset
electricity, medium voltage
Uncertainty
-52.7% / +76.7% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
kWh
Kr Process gasg · -75% / +100%
Source citations
Background data
ecoinvent 3.12
Background dataset
krypton, gaseous
Uncertainty
-75% / +100% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
N2 Process gasg · -22.5% / +25.3%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
nitrogen, liquid
Uncertainty
-22.5% / +25.3% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
O2 Process gasg · -33.4% / +100%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
oxygen, liquid
Uncertainty
-33.4% / +100% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
H2O Process gasg · -50.1% / +100%
Background data
ecoinvent 3.12
Background dataset
water, deionised
Uncertainty
-50.1% / +100% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
HCl Process gasg · -50% / +150%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
hydrochloric acid, without water, in 30% solution state
Uncertainty
-50% / +150% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Ar Process gasg · ±47%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
argon, liquid
Uncertainty
±47% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
H2 Process gasg · -50% / +100.1%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
hydrogen, gaseous, low pressure
Uncertainty
-50% / +100.1% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Compressed air (tool) Process gasg · -33.4% / +66.6%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
compressed air, 700 kPa gauge
Uncertainty
-33.4% / +66.6% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Compressed air Process gasg · -29.6% / +40%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
compressed air, 700 kPa gauge
Uncertainty
-29.6% / +40% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Copper sulfate Process chemicalg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
copper sulfate
Notes
From Cu plating bath (CuSO4 + H2SO4 + accelerator/suppressor) (33.0% copper sulfate). Cu source of the acid bath; resolves via the copper sulfate entry (GLO market).
Uncertainty
No range defined.
Unit
g
Sulfuric acid Process chemicalg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
sulfuric acid
Notes
From Cu plating bath (CuSO4 + H2SO4 + accelerator/suppressor) (66.0% sulfuric acid). Conductivity acid of the bath; resolves via the sulfuric acid entry (RoW default for TW/KR/JP).
Uncertainty
No range defined.
Unit
g
Cu plating bath (CuSO4 + H2SO4) Process chemicalg · -33.3% / +50%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
proxy-mapped
Background dataset
copper sulfate
Uncertainty
-33.3% / +50% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Copper sulfate pentahydrate (electroless) Process chemicalg · -16.7% / +33.3%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
copper sulfate
Uncertainty
-16.7% / +33.3% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Copper anodes (pattern plating) Process chemicalg · -12.8% / +14.9%
Derivation basis
  • No retrievable public document identified (metric clarification; per-substrate mass derivation retained in notes)

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
copper, cathode
Uncertainty
-12.8% / +14.9% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Formaldehyde solution Process chemicalg · ±25%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
formaldehyde
Uncertainty
±25% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Palladium chloride Process chemicalg · -45.4% / +36.4%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
proxy-mapped
Background dataset
palladium
Notes
Proxy mapping uses 60% of the material mass.
Uncertainty
-45.4% / +36.4% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Nickel sulfate hexahydrate Process chemicalg · ±20%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
nickel sulfate
Uncertainty
±20% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Sodium hypophosphite Process chemicalg · ±25%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
proxy-mapped
Background dataset
sodium phosphate
Uncertainty
±25% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Gold potassium cyanide Process chemicalg · -15.1% / +13.2%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
proxy-mapped
Background dataset
gold
Notes
Proxy mapping uses 68.4% of the material mass.
Uncertainty
-15.1% / +13.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Potassium permanganate Process chemicalg · -40% / +20%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
potassium permanganate
Uncertainty
-40% / +20% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Dry film photoresist Process chemicalg · ±25%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
proxy-mapped
Background dataset
methyl methacrylate
Uncertainty
±25% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Flux (no-clean) Process chemicalg · -66.4% / +68%
Derivation basis
  • Typical flux application

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
flux, for wave soldering
Uncertainty
-66.4% / +68% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Flux (water soluble) Process chemicalg · -40% / +100%
Derivation basis
  • Flux type for FOWLP solder ball attach

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
flux, for wave soldering
Uncertainty
-40% / +100% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Capillary underfill (epoxy) Process chemicalg · -33.3% / +50%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
epoxy resin insulator, SiO2
Uncertainty
-33.3% / +50% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Flux paste Process chemicalg · -60% / +100%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
flux, for wave soldering
Uncertainty
-60% / +100% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Stencil cleaner (IPA) Process chemicalg · -50% / +100%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
isopropanol
Uncertainty
-50% / +100% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Lid adhesive (silicone) Process chemicalg · -69% / +343.1%
Source citations
Background data
ecoinvent 3.12
Background dataset
silicone product
Uncertainty
-69% / +343.1% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Silicon Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
silicon, electronics grade
Uncertainty
No range defined.
Unit
kg
Electroplated Cu Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
copper, cathode
Uncertainty
No range defined.
Unit
kg
Cu pillar + SnAg Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
copper, cathode
Uncertainty
No range defined.
Unit
kg
SnAg Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
composite
Background dataset
Modelled as a composite of its constituent materials.
Uncertainty
No range defined.
Unit
kg
BT + ABF Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
proxy-mapped
Background dataset
epoxy resin insulator, SiO2
Uncertainty
No range defined.
Unit
kg
SAC305 Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
composite
Background dataset
Modelled as a composite of its constituent materials.
Uncertainty
No range defined.
Unit
kg
Cu Materialkg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
copper, cathode
Uncertainty
No range defined.
Unit
kg
Thermal interface material Materialkg · -50.8% / +146.2%
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12
Background dataset
silicone product
Uncertainty
-50.8% / +146.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
kg

Outputs and waste

Wastewater Wastewaterm3 · -35.3% / +43.2%
Derivation basis
  • Calculated from the water balance: fresh-water input minus evaporation.

No source is attached to this row.

Source citations
Not stated
Background data
carried, no background dataset
Background dataset
No treatment route recorded for this output.
Uncertainty
-35.3% / +43.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
m3
Spent photoresist (liquid spin-off) Solid wasteg · -24.4% / +97%
Source citations
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, hazardous waste incineration, with energy recovery
Uncertainty
-24.4% / +97% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Spent photoresist (retained film) Solid wasteg · -22.9% / +57.3%
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, hazardous waste incineration, with energy recovery
Uncertainty
-22.9% / +57.3% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Intact un-eroded sputter target body (Ta) Solid wasteg · -33.3% / +66.7%
Source citations
Background data
ecoinvent 3.12 treatment route
Background dataset
material recovery (material dependent - typically recycled)
Uncertainty
-33.3% / +66.7% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Spent sputter targets (Cu) Solid wasteg · -44.2% / +45.5%
Source citations
Background data
ecoinvent 3.12 treatment route
Background dataset
market for copper scrap, sorted, pressed
Uncertainty
-44.2% / +45.5% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Copper in wastewater-treatment sludge/recovery Solid wasteg · -15.9% / +16.6%
Source citations (dataset-level)
Background data
ecoinvent 3.12 treatment route
Background dataset
market for copper scrap, sorted, pressed
Uncertainty
-15.9% / +16.6% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
CMP slurry waste Solid wasteg · -27.8% / +33.2%
Derivation basis
  • Copper bulk, barrier and buff slurry (the dispensed-volume input rows on this record)

The sources below are this dataset's own bibliography. They are not tied to this row.

Source citations (dataset-level)
Inherited from this dataset's own bibliography, not tied to this row:
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, underground deposit
Uncertainty
-27.8% / +33.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Spent CMP pads Solid wasteg · -51.6% / +679.2%
Derivation basis
  • REEL derivation: CMP pad mass from pad geometry and polyurethane density

The sources for this row are listed below.

Source citations
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, underground deposit
Uncertainty
-51.6% / +679.2% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Photoresist solids in NMP strip bath Solid wasteg · -33.4% / +66.6%
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, hazardous waste incineration, with energy recovery
Uncertainty
-33.4% / +66.6% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Silicon cake (from DBGW filtration) Solid wasteg · -90.6% / +300%
Derivation basis
  • No retrievable public document identified

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of inert waste, sanitary landfill
Uncertainty
-90.6% / +300% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Mixed process waste Solid wasteg · ±0.9%
Source citations
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of inert waste, sanitary landfill
Uncertainty
±0.9% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Spent dry film resist Solid wasteg · ±25%
Derivation basis
  • Calculated from the mass balance of spent materials and consumables, with treatment selected from the waste classification.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of waste plastic, mixture, municipal incineration
Uncertainty
±25% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Manganate desmear sludge Solid wasteg · -40% / +35%
Source citations (dataset-level)
Inherited from this dataset's own bibliography, not tied to this row:
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, underground deposit
Uncertainty
-40% / +35% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Solder mask develop sludge (unpolymerized resin) Solid wasteg · -34.8% / +30.4%
Derivation basis
  • No retrievable public document identified

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of waste plastic, mixture, municipal incineration
Uncertainty
-34.8% / +30.4% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Phosphorus in wastewater-treatment sludge Solid wasteg · -47% / +46.5%
Derivation basis
  • Derived: elemental phosphorus balance, the phosphorus reaching treatment less the post-treatment residual

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, underground deposit
Uncertainty
-47% / +46.5% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Dicing slurry (Si/EMC/Cu particles) Solid wasteg
Derivation basis
  • No retrievable public document identified

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, underground deposit
Uncertainty
No range defined.
Unit
g
Flux residue on stencil Solid wasteg
Derivation basis
  • Calculated from the mass balance of spent materials and consumables, with treatment selected from the waste classification.

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of hazardous waste, hazardous waste incineration, with energy recovery
Uncertainty
No range defined.
Unit
g
Broken dies Solid wasteg
Derivation basis
  • Engineering estimate based on yield loss

No source is attached to this row.

Source citations
Not stated
Background data
ecoinvent 3.12 treatment route
Background dataset
treatment of inert waste, sanitary landfill
Uncertainty
No range defined.
Unit
g

Emissions to air

8 elementary flows released to air by this dataset's own operations. Quantities are not published; they ship with the dataset on Circa.

VOCs Emission to airg
Compartment
Air (non-urban air or from high stacks)
ecoinvent 3.12 elementary flow
NMVOC, non-methane volatile organic compounds
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
SF6 Emission to airg
Derivation basis
  • Calculated from the sulfur hexafluoride purchased for this step and the central gas-fate utilisation and destruction-removal efficiency for thermal abatement

The sources below are this dataset's own bibliography. They are not tied to this row.

Source citations (dataset-level)
Inherited from this dataset's own bibliography, not tied to this row:
Compartment
Air (non-urban air or from high stacks)
CAS number
2551-62-4
ecoinvent 3.12 elementary flow
Sulfur hexafluoride
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
C4F8 Emission to airg
Derivation basis
  • Calculated from the octafluorocyclobutane purchased for this step and the central gas-fate utilisation and destruction-removal efficiency for thermal abatement

The sources below are this dataset's own bibliography. They are not tied to this row.

Source citations (dataset-level)
Inherited from this dataset's own bibliography, not tied to this row:
Compartment
Air (non-urban air or from high stacks)
CAS number
115-25-3
ecoinvent 3.12 elementary flow
Tetrafluoromethane
Notes
Proxied to CF4 (Tetrafluoromethane) for ecoinvent linking. The two substances are not equivalent: this one has the substantially greater warming effect of the pair, so any characterization performed through this proxy link understates it. Use the substance's own factor rather than the proxy's.
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
HCl Emission to airg
Derivation basis
  • Calculated as an air release, from a mass balance on the process gases going in, with the destruction or removal efficiency of any point-of-use abatement applied.

No source is attached to this row.

Source citations
Not stated
Compartment
Air (non-urban air or from high stacks)
CAS number
7647-01-0
ecoinvent 3.12 elementary flow
Hydrochloric acid
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Volatile organic compounds (VOCs) Emission to airg
Derivation basis
  • Calculated as an air release, from a mass balance on the process gases going in, with the destruction or removal efficiency of any point-of-use abatement applied.

No source is attached to this row.

Source citations
Not stated
Compartment
Air (non-urban air or from high stacks)
ecoinvent 3.12 elementary flow
NMVOC, non-methane volatile organic compounds
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
HCHO Emission to airg
Derivation basis
  • Calculated as an air release, from a mass balance on the process gases going in, with the destruction or removal efficiency of any point-of-use abatement applied.

No source is attached to this row.

Source citations
Not stated
Compartment
Air (non-urban air or from high stacks)
CAS number
50-00-0
ecoinvent 3.12 elementary flow
Formaldehyde
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Flux volatiles Emission to airg
Compartment
Air (non-urban air or from high stacks)
ecoinvent 3.12 elementary flow
NMVOC, non-methane volatile organic compounds
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
VOCs (from underfill cure) Emission to airg
Derivation basis
  • Calculated as an air release, from a mass balance on the process gases going in, with the destruction or removal efficiency of any point-of-use abatement applied.

No source is attached to this row.

Source citations
Not stated
Compartment
Air (non-urban air or from high stacks)
ecoinvent 3.12 elementary flow
NMVOC, non-methane volatile organic compounds
Uncertainty
No range defined.
Unit
g

Emissions to water

9 elementary flows released to water by this dataset's own operations. Quantities are not published; they ship with the dataset on Circa.

Cl- Emission to waterg
Compartment
Water (surface water)
CAS number
16887-00-6
ecoinvent 3.12 elementary flow
Chloride
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Cu2+ Emission to waterg
Source citations
Compartment
Water (surface water)
Formula
Cu
CAS number
7440-50-8
ecoinvent 3.12 elementary flow
Copper ion
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Sn2+ Emission to waterg
Source citations
Compartment
Water (surface water)
Formula
Sn
CAS number
7440-31-5
ecoinvent 3.12 elementary flow
Tin ion
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Ammonium Emission to waterg
Source citations
Compartment
Water (surface water)
Formula
NH4+
CAS number
14798-03-9
ecoinvent 3.12 elementary flow
Ammonium
Notes
TMAH biodegrades in WWTP; NH4+ mass fraction 18.04/91.15
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Dissolved organics (COD) Emission to waterg
Source citations
Compartment
Water (surface water)
ecoinvent 3.12 elementary flow
COD, Chemical Oxygen Demand
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Si Emission to waterg
Derivation basis
  • No retrievable public document identified

The sources for this row are listed below.

Source citations
Compartment
Water (surface water)
CAS number
7440-21-3
ecoinvent 3.12 elementary flow
Silicon
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Ni Emission to waterg
Derivation basis
  • Calculated as a release to water, from a contaminant mass balance on the process chemistry.

No source is attached to this row.

Source citations
Not stated
Compartment
Water (surface water)
Formula
Ni2+
CAS number
14701-22-5
ecoinvent 3.12 elementary flow
Nickel II
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
CN- Emission to waterg
Derivation basis
  • Calculated as a release to water, from a contaminant mass balance on the process chemistry.

No source is attached to this row.

Source citations
Not stated
Compartment
Water (surface water)
CAS number
57-12-5
ecoinvent 3.12 elementary flow
Cyanide
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g
Phosphorus (from hypophosphite) Emission to waterg
Source citations
  • EU STM BREF 2006 §2.13.1.13 and §4.16.9.2; EPA E&EC Study Report 2022 Table 13
Compartment
Water (surface water)
Formula
P
CAS number
7723-14-0
ecoinvent 3.12 elementary flow
Phosphorus
Uncertainty
A minimum-maximum range is defined for this flow. Bounds ship with the dataset on Circa.
Unit
g

Flows not quantified

3 flows are recorded for this dataset but carry no quantity — cut off below the significance threshold, or with no background dataset available. They remain inside the declared system boundary; each is listed with its reason.

Cut off - below the significance threshold (3)

Ne Process gasg · -75% / +50%
Source citations
Background data
cut off
Background dataset
Not applicable: this flow is not quantified in the inventory.
Reason
Neon consumption (excimer-laser buffer gas) is recorded in this inventory. Upstream production is excluded under the declared cut-off criteria. It is an inert noble gas recovered as a byproduct of cryogenic air separation, with a contribution below the significance threshold.
Uncertainty
-75% / +50% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g
Organic additive package (SPS/PEG/leveler) Process chemicalg
Derivation basis
  • Calculated from per-operation consumption, operation counts, and manufacturing yield.

No source is attached to this row.

Source citations
Not stated
Background data
cut off
Background dataset
Not applicable: this flow is not quantified in the inventory.
Notes
From Cu plating bath (CuSO4 + H2SO4 + accelerator/suppressor) (1.0% organic additives). Trace organics carried visibly as a documented cutoff row so the decomposition conserves the authored bath mass exactly.
Reason
Evaluated cutoff: a proprietary SPS accelerator / PEG suppressor / leveler package making up 1% of the plating bath. At sub-gram scale it is far below 1% of package input mass and energy and is insignificant across all impact categories (GWP, toxicity, resource depletion, water); no honest ecoinvent target exists for the proprietary organics. Documented per the boundary-inclusion policy: map what is mappable, under-include the un-modelable trace organics with an explicit note rather than proxying them to something unrelated.
Uncertainty
No range defined.
Unit
g
SnAg plating bath (MSA-based) Process chemicalg · -40% / +60%
Derivation basis
  • Solder plating bath

No source is attached to this row.

Source citations
Not stated
Background data
cut off
Background dataset
Not applicable: this flow is not quantified in the inventory.
Reason
The tin-silver plating bath is consumed in trace quantity and its formulation is complex, recorded in this inventory. This row covers the bath chemistry alone; the tin and silver the bath deposits onto the package are not carried on it. Where this dataset lists no separate deposited-solder material row, the deposited tin and silver are absent from the dataset altogether rather than accounted for elsewhere, and whether they belong inside this boundary is an open question this record does not settle. The bath chemistry falls below the declared cut-off threshold, so no upstream production dataset is attached.
Uncertainty
-40% / +60% around the published quantity. The bounds themselves ship with the dataset on Circa.
Unit
g

Limitations and unquantified flows (3)

Limits this dataset declares about itself: first any limit stated in its own description, then any limit it declares flow by flow, grouped by channel. Each entry below is the model's own disclosure.

  • The uncertainty range on this dataset's abated fluorinated-gas emissions to air is the range of the incoming gas, carried through in proportion. It does not widen for how much of the gas is consumed in the reaction, or for how completely the abatement destroys what is left; both of those are held at their central values on this dataset. Wafer datasets do carry those two through into the range, so the range published here is narrower than the one a wafer dataset publishes for the same kind of emission.
  • These materials are used at a step of the modelled flow and are also carried by this dataset's own material list. Each is counted once, on that list, and the step does not book it again: TSV barrier PVD (Ta/TaN) uses Cu sputtering target; TSV Cu seed PVD uses Cu sputtering target; Microbump formation (UBM + Cu pillar + SnAg cap) uses Copper (anode or replenishment) and SnAg solder; C4 bump formation (interposer bottom) uses Copper (anode or replenishment) and SnAg solder; Mass reflow (chip on wafer) uses SAC305 solder balls; Solder ball attach uses SAC305 solder balls; TIM dispense uses Thermal Interface Material.
  • Some consumable pulls referenced by the modelled process steps did not resolve to an inventory row and are absent from this dataset. They are itemised in the dataset's own export audit.

The flows above are this dataset's own records. What follows are the scope rules set once for the whole database in the methodology report, repeated here so every dataset page carries them.

Database-wide boundary policy — applies to every REEL dataset

These boundaries are set once for the whole database, in Chapter 2 of the methodology report, and apply to this dataset wherever they are relevant to it. The excluded flows listed above are specific to this dataset.

Use phase
Product operation is outside the cradle-to-gate scope.
End-of-life treatment
Recycling and disposal are outside the cradle-to-gate scope.
Distribution and retail
The gate is a finished component ready for integration into a higher-level assembly.
Inbound transport of raw materials
Transport of purchased raw materials to the manufacturing facility is already inside the upstream "market for" datasets that users link to a background database, so it is not modelled a second time here. This does not cover freight between REEL production stages, which is modelled where a dataset authors it.
Returnable shipping containers
Where freight between production stages is modelled, the mass moved is the product itself. The shipping container (FOSB, SEMI M31) is returnable capital equipment whose per-trip share is unsourced, so its tare is excluded from the transport effort.
Photomask fabrication
A mask set's embodied burden is amortised across a high-volume production run and is not attributed per wafer. Users assessing low-volume production should add mask fabrication separately; the methodology report gives the basis for the exclusion.
Employee transport, administration and R&D overhead
Employee transportation, facility administration and R&D/pilot-production overhead are outside scope.
Capital goods
Manufacturing equipment, cleanroom construction and facility infrastructure are excluded, on the grounds of absent public data on equipment embodied energy, uncertainty in equipment lifetime and allocation, common practice in electronics LCA, and a focus on the operational inventory. Future versions may include capital goods when sufficient public data becomes available.
Precious metal recovery credits
Scrap recovery credits for precious metals are excluded pending data availability.
Wafer reclaim
Test wafers and scrap are outside the system boundary.

Inside the boundary, linked rather than modelled

Silicon ingot growth and wafer slicing
Inside the cradle-to-gate scope, but treated as upstream material inputs linked to background databases rather than modelled as REEL processes.
Freight between production stages
Where a dataset's product moves between REEL production stages - wafer fabrication to the packaging site, for example - that leg is authored as a transport service and linked to an ecoinvent freight activity. It is measured as a transport effort in tonne-kilometres, not as a mass. Route distances are authored per route class with a stated band; a lower bound of zero is a modelling statement that the two sites can be co-located, not a missing value.

Cut-off criteria

A flow is excluded from a process inventory when it contributes less than 1 % of the total mass of inputs to that unit process, or less than 1 % of its total energy input. The denominator is total process inputs, not product mass. That distinction matters in semiconductor manufacturing, where the input mass of water, chemicals and gases greatly exceeds the product mass, so the threshold removes only genuinely minor flows.

Included regardless of the cut-off

  • Perfluorocarbons (CF4, C2F6, SF6, NF3) - high GWP, EPA regulated
  • Heavy metals (Pb, Cd, Hg, Cr(VI)) - RoHS regulated, high toxicity
  • Volatile organics (photoresist solvents, PGMEA) - air quality
  • Precious metals (Au, Ag, Pd, Pt) - high embodied impacts
  • Ozone-depleting substances (legacy CFCs, HCFCs) - Montreal Protocol